+86 18575592563

  • Home
  • About
  • Medical Devices
    • Fetal Doppler
    • Fetal /Maternal monitor
    • Medical Pump
    • Infusion warmer
    • Ultrasound machine
    • ECG
    • Vein Finder
    • Syringe Destroyer
    • Vascular Doppler
    • Infrared thermometer
  • Laborotary Diagnostics
    • Hemoglobin(HPLC)Analyzer
    • Coagulation Analyzer
    • Immunoassay Analyzer
    • Hematololgy Analyer(CBC)
    • Reagents
  • Annimal Medical Devices
    • Animal Medical Pump
    • Annimal medical monitor
  • Contact
  • 更多
    • Home
    • About
    • Medical Devices
      • Fetal Doppler
      • Fetal /Maternal monitor
      • Medical Pump
      • Infusion warmer
      • Ultrasound machine
      • ECG
      • Vein Finder
      • Syringe Destroyer
      • Vascular Doppler
      • Infrared thermometer
    • Laborotary Diagnostics
      • Hemoglobin(HPLC)Analyzer
      • Coagulation Analyzer
      • Immunoassay Analyzer
      • Hematololgy Analyer(CBC)
      • Reagents
    • Annimal Medical Devices
      • Animal Medical Pump
      • Annimal medical monitor
    • Contact

+86 18575592563

  • Home
  • About
  • Medical Devices
    • Fetal Doppler
    • Fetal /Maternal monitor
    • Medical Pump
    • Infusion warmer
    • Ultrasound machine
    • ECG
    • Vein Finder
    • Syringe Destroyer
    • Vascular Doppler
    • Infrared thermometer
  • Laborotary Diagnostics
    • Hemoglobin(HPLC)Analyzer
    • Coagulation Analyzer
    • Immunoassay Analyzer
    • Hematololgy Analyer(CBC)
    • Reagents
  • Annimal Medical Devices
    • Animal Medical Pump
    • Annimal medical monitor
  • Contact

Laboratory Diagnostics

Fully automated Hemoglobin Analyzer LH900P

This model is for small size lab

 900P HbA1c Analyser uses ion exchange liquid chromatography for quantitative determination of the content of glycated hemoglobin (HbA1c) in human whole blood. 

After glycated hemoglobin in samples elutes from the chromatography column, 

the analyzer can provide the results of HbA1c (%, NGSP) and HbA1c (mmol/mol, 

IFCC). Meanwhile, the chromatogram can display HbA1a, HbA1b, HbF, LA1c, SA1c 

(HbA1c), A0 and other components, and the estimated average blood glucose can be 

calculated by the conversion equation provided in ADA, EASD and IDF researches 

(Diabetes Care 2008; 31:1-6). Also, common abnormal haemoglobin can be reported.

Features

· Gold standard methodology (HPLC)

· High precision with CV <1.5%

· Dual wavelengths to avoid background interference

· No interference of main Hb Varaints and high HbF

· Thalassemia mode available for HbF and Hb2 report

· Highly automated system with automatic cap piercing

· User friendly operation

· NGSP & IFCC certified

Comparison between models

* Test Mode: HbA1c

*Test Items: HbF, HbA1c,  Variant Window

* Sample Loader: 5

* Cap Piercing :No

* Variant Report: No

* HbA1c Test Range:3 - 18%

* Test Time (Minutes) :2.2 ( HbA1c mode)

* Reagents :A, B, L S oluton

* Precision:( Foil bagged)

* Dimension· : HbA1c(CV≤1 . 5%) 

Fully automated Hemoglobin Analyzer LH8

This model is for Mediun Size lab 

  

Analyzer(HPLC) uses ion exchange high performance liquid 

chromatography for quantitative determination of the content of glycated hemoglobin 

(HbA1c) in human whole blood. 

After glycated hemoglobin in samples elutes from the chromatography column, the 

analyzer can provide the results of HbA1c (%, NGSP) and HbA1c (mmol/mol, IFCC). 

Meanwhile, the chromatogram can display HbA1a, HbA1b, HbF, LA1c, SA1c (HbA1c), A0 

and other components, and the estimated average blood glucose can be calculated by the 

conversion equation provided in ADA, EASD and IDF researches (Diabetes Care 2008; 

31:1-6); also, common abnormal haemoglobin can be reported.


· Gold standard methodology (HPLC)

· High precision with CV <1.5%

· Dual wavelengths to avoid background interference

· No interference of main Hb Varaints and high HbF

· Thalassemia mode available for HbF and Hb2 report

· Highly automated system with automatic cap piercing

· User friendly operation

· NGSP & IFCC certified

Comparison between models

* Test Mode:  HbA1c + Thalassemia 

*Test Items:  HbF, HbA2, HbA1c,    Hb Variant (E/ D/ S/ C) 

* Sample Loader: 10

* Cap Piercing :Yes

* Variant Report:Yes

* HbA1c Test Range:3 - 18%

* Test Time (Minutes) :2.2 ( HbA1c mode) 6.0 ( Thalassemia mode)

* Reagents :A, B, L S oluton  (Bottled)

* Precision: HbA1c(CV≤1 . 5%) 

* Dimension· :540(H)×360(W)×600(D)mm

Fully automated Hemoglobin Analyzer H9

This model is for Big size lab

 This diagnosis device that is used for disease screening. When diagnosing 

disease, clinicians should take clinical examination results or other test result into consideration.

LH9 hemoglobin Analyzer(HPLC) is a fully automated system composed of Ion-exchange 

chromatography testing system and sampling system. It could be connected to LIS/HIS to transfer data. 

LH9 Analyzer(HPLC) adopts High Performance Liquid Chromatography (HPLC) to measuring the 

content of HbA1c in human blood.

Features

· Gold standard methodology (HPLC)

· High precision with CV <1.5%

· Dual wavelengths to avoid background interference

· No interference of main Hb Varaints and high HbF

· Thalassemia mode available for HbF and Hb2 report

· Highly automated system with automatic cap piercing

· User friendly operation

· NGSP & IFCC certified

Comparison between models

Features

* Test Mode:  HbA1c + Thalassemia 

*Test Items:  HbF, HbA2, HbA1c,    Hb Variant (E/ D/ S/ C) 

* Sample Loader: 110

* Cap Piercing :Yes

* Variant Report:Yes

* HbA1c Test Range:3 - 18%

* Test Time (Minutes) :2.2 ( HbA1c mode) 6.0 ( Thalassemia mode)

* Reagents :A, B, L S oluton  (Bottled)

* Precision: HbA1c(CV≤1 . 5%) 

* Dimension· :580(H)×500(W)×520(D)mm