900P HbA1c Analyser uses ion exchange liquid chromatography for quantitative determination of the content of glycated hemoglobin (HbA1c) in human whole blood.
After glycated hemoglobin in samples elutes from the chromatography column,
the analyzer can provide the results of HbA1c (%, NGSP) and HbA1c (mmol/mol,
IFCC). Meanwhile, the chromatogram can display HbA1a, HbA1b, HbF, LA1c, SA1c
(HbA1c), A0 and other components, and the estimated average blood glucose can be
calculated by the conversion equation provided in ADA, EASD and IDF researches
(Diabetes Care 2008; 31:1-6). Also, common abnormal haemoglobin can be reported.
Features
· Gold standard methodology (HPLC)
· High precision with CV <1.5%
· Dual wavelengths to avoid background interference
· No interference of main Hb Varaints and high HbF
· Thalassemia mode available for HbF and Hb2 report
· Highly automated system with automatic cap piercing
· User friendly operation
· NGSP & IFCC certified
* Test Mode: HbA1c
*Test Items: HbF, HbA1c, Variant Window
* Sample Loader: 5
* Cap Piercing :No
* Variant Report: No
* HbA1c Test Range:3 - 18%
* Test Time (Minutes) :2.2 ( HbA1c mode)
* Reagents :A, B, L S oluton
* Precision:( Foil bagged)
* Dimension· : HbA1c(CV≤1 . 5%)
This model is for Mediun Size lab
Analyzer(HPLC) uses ion exchange high performance liquid
chromatography for quantitative determination of the content of glycated hemoglobin
(HbA1c) in human whole blood.
After glycated hemoglobin in samples elutes from the chromatography column, the
analyzer can provide the results of HbA1c (%, NGSP) and HbA1c (mmol/mol, IFCC).
Meanwhile, the chromatogram can display HbA1a, HbA1b, HbF, LA1c, SA1c (HbA1c), A0
and other components, and the estimated average blood glucose can be calculated by the
conversion equation provided in ADA, EASD and IDF researches (Diabetes Care 2008;
31:1-6); also, common abnormal haemoglobin can be reported.
· Gold standard methodology (HPLC)
· High precision with CV <1.5%
· Dual wavelengths to avoid background interference
· No interference of main Hb Varaints and high HbF
· Thalassemia mode available for HbF and Hb2 report
· Highly automated system with automatic cap piercing
· User friendly operation
· NGSP & IFCC certified
Comparison between models
* Test Mode: HbA1c + Thalassemia
*Test Items: HbF, HbA2, HbA1c, Hb Variant (E/ D/ S/ C)
* Sample Loader: 10
* Cap Piercing :Yes
* Variant Report:Yes
* HbA1c Test Range:3 - 18%
* Test Time (Minutes) :2.2 ( HbA1c mode) 6.0 ( Thalassemia mode)
* Reagents :A, B, L S oluton (Bottled)
* Precision: HbA1c(CV≤1 . 5%)
* Dimension· :540(H)×360(W)×600(D)mm
This diagnosis device that is used for disease screening. When diagnosing
disease, clinicians should take clinical examination results or other test result into consideration.
LH9 hemoglobin Analyzer(HPLC) is a fully automated system composed of Ion-exchange
chromatography testing system and sampling system. It could be connected to LIS/HIS to transfer data.
LH9 Analyzer(HPLC) adopts High Performance Liquid Chromatography (HPLC) to measuring the
content of HbA1c in human blood.
Features
· Gold standard methodology (HPLC)
· High precision with CV <1.5%
· Dual wavelengths to avoid background interference
· No interference of main Hb Varaints and high HbF
· Thalassemia mode available for HbF and Hb2 report
· Highly automated system with automatic cap piercing
· User friendly operation
· NGSP & IFCC certified
Features
* Test Mode: HbA1c + Thalassemia
*Test Items: HbF, HbA2, HbA1c, Hb Variant (E/ D/ S/ C)
* Sample Loader: 110
* Cap Piercing :Yes
* Variant Report:Yes
* HbA1c Test Range:3 - 18%
* Test Time (Minutes) :2.2 ( HbA1c mode) 6.0 ( Thalassemia mode)
* Reagents :A, B, L S oluton (Bottled)
* Precision: HbA1c(CV≤1 . 5%)
* Dimension· :580(H)×500(W)×520(D)mm