The device uses biochemical reaction to detect ATP content. When used, samples are collected with pre-wetted water swabs, and the ATP swab is wetted with buffer, which helps to extract the biological material (ATP) from a dry or moist surface. The swab contains a reagent that cleaves the cell membrane, which releases the intracellular ATP and reacts with the specific enzyme contained in the reagent to produce light. The luminescence value is measured by a fluorescence illuminance meter. The number of microorganisms is proportional to the luminous value.
ATP cell : colony counter Instrument features:
High sensitivity - 5X10-18mol / ATP
Speed - conventional culture method 18-24h or more, and ATP only need a dozen seconds.
Feasibility - The number of microbes has a clear correlation with the ATP contained in the microorganisms. By detecting the ATP content, the number of microorganisms in the reaction can be obtained indirectly.
Maneuverability - Traditional training methods need to be carried out by trained technicians in the laboratory; and the ATP fast cleanliness detection operation is very simple and can be operated by the general staff only by simple training.
Production of the ATP fluorescence detector was the Ministry of Science and Technology "scientific and technological innovation projects"
ATP cell : colony counter The main parameters:
1, large screen clear LCD display
2, the detection accuracy: 5 × 10-18mol / ATP?
3, detection range: 0 to 9999 RLUs
4, detection time: 15 seconds
5, detection error: ± 5 RLUs
6, the operating temperature range: 5 ℃ to 40 ℃
7, the operating humidity range: 20-85%
8, ATP recovery: 90-110%
9, detection mode: RLU, coliform screening
10,50 user ID settings
11, can set the number of results limit: 250
12,2000 memory storage
13, automatically determine the qualified
14, automatic statistical pass rate
15, built-in self-calibration light source
16, boot 30 seconds self test
17, with RS232 interface (with USB interface), the results can be uploaded to the PC
18, instrument size (W × H × D): 192mm × 87mm × 34mm
19, the use of two standard 5 batteries or rechargeable lithium battery
21, standby state (20 ℃): 6 months
22, Chinese operation manual
23, stable liquid luciferase
24, wetting the integrated collection of swabs
Random configuration: ATP fluorescence detector (handheld) host, instrument package, lanyard, battery, PC data cable, data analysis software, Chinese operation manual
Matching Products: ATP Fluorescence Detection Swab, ATP Sample Collector